Self-test
International
regulations
require
that
Self-testing
of
the
PLB
should
only
be
carried
out
in
the
first
five
minutes
of
any
hour.
Check
the
PLB
monthly
and
check
the
battery
is
in
date.
Self-test
verifies
operation
of
the
PLB
by
checking
key
features
including
battery
voltage
and
406
MHz
and
121.5
MHz
alert
transmitters.
Important
Each
self-test
draws
small
amounts
of
energy
from
the
battery
pack.
Unnecessary
testing
of
the
PLB
may
subsequently
reduce
the
run
time
of
the
PLB
in
an
emergency.
On
average,
the
PLB
should
only
be
self-tested
12
times
per
year,
or
a
total
of
60
times
across
the
5
year
battery
lifetime.
To
operate
self-test,
use
the
Test/OFF
button,
located
under
the
flexible
handle
of
the
red
anti-tamper
cover.
i
Open
the
flip-top
lid.
Do
NOT
pull
off
the
red
anti-tamper
cover.
i
Slide
a
finger
under
the
flexible
handle
of
the
anti-tamper
cover
to
locate
the
Test/OFF
button.
i
Hold
down
the
Test/OFF
button
for
10
seconds.
i
(red
ON
indicator
light
will
illuminate)
i
Self-test
pass
is
indicated
by
3
flashes
of
the
green
indicator
light.
i
A
failed
self-test
is
indicated
by
3
flashes
of
the
red
ON
indicator
light
i
The
PLB
will
switch
off
once
the
self-test
has
finished
Self-test
i
Release
the
button
and
close
the
flip-top
lid.
Important:
While
self-testing
keep
your
fingers
away
from
the
top
of
the
PLB
as
the
close
proximity
of
any
objects
can
affect
the
results
of
the
self-test.